Home    DTS-1000/2000 Thyristor Accessory For Discrete Device System
Picture2

DTS-1000/2000 Thyristor Accessory For Discrete Device System

Through addition of this accessory, DTS-1000 test system will be able to test thyristor products. Most common test programs are: IGT1-4 quadrant trigger current, VGT1-4 quadrant trigger voltage, IH1-4 quadrant holding current, VTM, Ilatch and other thyristor programs
Return
Contact us

DETAILS

 

Thyristor Test Range and Accuracy

 

Test Item Item Name Measurement Range & Accuracy Forcing Range & Accuracy
Leakage Current

IDRM(SR) IRRM

000.0pA9.999mA

000.0pA9.999nA  ±2%+10pA

00.00nA99.99nA  ±1%+2digit

000.0nA999.9mA  ±0.5%+2digit

HV: 1.00V999.9V ±0.5%+20mV

Breakdown Voltage VDRM(SR) VRRM VRGM 0.000V~999.9V  ±0.5%+2digit

Current: 100nA50.0mA ±0.5%+3nA

VMAX: 000V999.9V     ±10%+2V

Forward Voltage VFGM 00.00mV~20.00V  ±0.5%+2mV

Current: 

100nA20.0A  ±0.5%+3nA

On Voltage VTM 00.00mV~20.00V  ±0.5%+2mV

IT: 100nA9.99A ±0.5%+3nA

IG: 00.0nA99.9A  ±0.5%+3nA

Gate Trigger Current

IGT1 (T+G+)

IGT2 (T+G-)

IGT3 (T-G-)

IGT4 (T-, G+)

000.0mV20.00V  ±1.0%+2mV

ON Voltage Value:  ±0.019.99V

100mV30.00V  ±0.5%+2mV

RL: (*1)

Gate Trigger Voltage

VGT1 (T+G+)

VGT2 (T+G-)

VGT3 (T- G-)

VGT4 (T- ,G+)

000.0mV20.00V  ±1.0%+2mV

ON Voltage Value:  ±0.019.99V

100mV30.00V  ±0.5%+2mV

RL: (*1)

Holding Current

IH 

0.000mV99.99mA  ±1.0%+2digit

ON Voltage

IT: 000mA9.99A ±0.5%+3nA

IG: 00.0mA99.9mA ±0.5%+3nA