Home
ꄲ
DTS-1000/2000 Thyristor Accessory For Discrete Device System
Through addition of this accessory, DTS-1000 test system will be able to test thyristor products. Most common test programs are: IGT1-4 quadrant trigger current, VGT1-4 quadrant trigger voltage, IH1-4 quadrant holding current, VTM, Ilatch and other thyristor programs
Thyristor Test Range and Accuracy
Test Item | Item Name | Measurement Range & Accuracy | Forcing Range & Accuracy |
Leakage Current |
IDRM(S,R) IRRM |
000.0pA~9.999mA 000.0pA~9.999nA ±2%+10pA 00.00nA~99.99nA ±1%+2digit 000.0nA~999.9mA ±0.5%+2digit |
HV: 1.00V~999.9V ±0.5%+20mV |
Breakdown Voltage | VDRM(S,R) VRRM VRGM | 0.000V~999.9V ±0.5%+2digit |
Current: 100nA~50.0mA ±0.5%+3nA VMAX: 000V~999.9V ±10%+2V |
Forward Voltage | VFGM | 00.00mV~20.00V ±0.5%+2mV |
Current: 100nA~20.0A ±0.5%+3nA |
On Voltage | VTM | 00.00mV~20.00V ±0.5%+2mV |
IT: 100nA~9.99A ±0.5%+3nA IG: 00.0nA~99.9A ±0.5%+3nA |
Gate Trigger Current |
IGT1 (T+, G+) IGT2 (T+, G-) IGT3 (T-, G-) IGT4 (T-, G+) |
000.0mV~20.00V ±1.0%+2mV ON Voltage Value: ±0.01~9.99V |
100mV~30.00V ±0.5%+2mV RL: (*1) |
Gate Trigger Voltage |
VGT1 (T+, G+) VGT2 (T+,G-) VGT3 (T- ,G-) VGT4 (T- ,G+) |
000.0mV~20.00V ±1.0%+2mV ON Voltage Value: ±0.01~9.99V |
100mV~30.00V ±0.5%+2mV RL: (*1) |
Holding Current |
IH |
0.000mV~99.99mA ±1.0%+2digit ON Voltage |
IT: 000mA~9.99A ±0.5%+3nA IG: 00.0mA~99.9mA ±0.5%+3nA |